Color Rendering Index (CRI)

CRI is a unit of measure that defines how well colors are rendered by different illumination conditions 
in comparison to a standard (i.e. a thermal radiator or daylight).
When CRI is calculated, it can be rated on a scale from 0 - 100. 
On this scale, a CRI of 100 would represent that all color samples illuminated by a light source in question, 
would appear to have the same color as those same samples illuminated by a reference source.  A negative CRIcan be calculated, but a goal for most lighting systems that produce white light is to have a positive CRI.

The technical CRI report was prepared by the 
CIE (Commission Internationale de l'Eclairage) Division 1 Vision and Colour.

Calculating CRI

    Colorimetric data must be transformed from CIE 1931 values (X, Y, Z, x, y) to the (u, v) coordinate of the 1960 diagram by means of the following:

    u = 4X/(X + 15Y + 3Z)                  (1-1a)
    v = 6Y/(X + 15Y + 3Z)                   (1-1b)

  1. To account for the adaptive color shift due to the different state of chromatic adaptation under the lamp to be tested, k, and under the reference illuminant, r, use the following formula:

    wpe16.gif (1766 bytes)
    (1-2)

    wpe18.gif (1461 bytes)

    The values u'k,i and v'k,i are the chromaticity coordinates of a test color sample, i, after the adaptive color shift, obtained by moving the light source to be tested to the reference illuminant, i.e. u'k = ur   v'k = vr and should not be mixed up with CIE 1976 u', v' coordinates.

  2. The functions c and d for use in equation (1-2) shall be calculated for the light source to be tested uk,vk, and the test color samples i under the light source to be tested uk,ivk,i according to the following:

    c = (4 - u - 10v)/v
    (1-3)
    d = (1.708v + 0.404 - 1.481u)/v

  3. Color imetric data must now be transformed into the 1964 Uniform Space coordinates by the following:

    wpe19.gif (1601 bytes) wpe1B.gif (1791 bytes)

    The values u'k urv'k = vr are the chromaticity coordinates of the light source to be tested after consideration of the adaptive color shift.  The values Yr,i and Yk,i must be normalized so thatYr = Yk = 100.

  4. One must calculate the difference between the resultant color shift of the test color sample under the test lamp k and illuminated by the reference r.   The following 1964 Colour Difference Formula should be used:

    wpe1C.gif (1361 bytes) (1-5)

  5. Calculate the Special Color Rendering Index, Ri, for each test color sample by the following:

    Ri = 100 - 4.6DEi (1-6)

  6. Calculate the general Color Rendering Index, CRI, by the following:

    wpe1.gif (1109 bytes) (1-7)

    The calculation uses 8 test color samples typically.

CIE test color samples:

Approximate

Munsell Notation Colour appearance under daylight 1 7,5 R 6/4 Light greyish red 2 5 Y 6/4 Dark greyish yellow 3 5 GY 6/8 Strong yellow green 4 2,5 G 6/6 Moderate yellowish green 5 10 BG 6/4 Light bluish green 6 5 PB 6/8 Light blue 72,5 P 6/8 Light violet 8 10 P 6/8 Light reddish purple 9 4,5 R 4/13 Strong red 10 5 Y 8/10 Strong yellow 11 4,5 G 5/8Strong green 12 3 PB 3/11 Strong blue 13 5 YR 8/4 Light yellowish pink (human complexion) 14 5 GY 4/4 Moderate olive green (leaf green)

wpeC.gif (3204 bytes)wpe5.gif (3199 bytes)
wpe6.gif (3270 bytes)wpe7.gif (3252 bytes)
wpe8.gif (3222 bytes)wpe9.gif (3294 bytes)
wpeA.gif (3268 bytes)wpeB.gif (3162 bytes)