Home > Technical Articles

EN/IEC 60061-3 All Lamp Cap Gauge

Article Description European standards Other standards REMARK
G01.01 “GO”GAUGE FOR E14 CAPS ON FINISHED LAMPS EN60061-3 IEC60061-3 7006-27F-1
G01.02 “NOT GO” GAUGE FOR E14 CAPS ON FINISHED LAMPS EN60061-3 IEC60061-3 7006-28B-1
G01.03 GAUGE FOR FINISHED LAMPS FITTED WITH E14 CAPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT EN60061-3 IEC60061-3 7006-55-2
G01.04 GAUGE FOR FINISHED LAMPS FITTED WITH E14 CAPS FOR TESTING CONTACT-MAKING EN60061-3 IEC60061-3 7006-54-2
G01.05 “GO”GAUGE FOR DIMENSION”S1” OF E14 CAPS ON FINISHED LAMPS EN60061-3 IEC60061-3 7006-27G-1
G01.06 “GO”GAUGES FOR SCREW THREADS OF LAMPHOLDERS E10,E14&E40 EN60061-3 IEC60061-3 7006-25-7
G01.07 “NOT GO”GAUGE FOR SCREW THREADS OF LAMPHOLDERS E10,EP10,EY10,E14,E27,E39&E40 EN60061-3 IEC60061-3 7006-26-4
G01.08 PLUG GAUGE FOR E14 LAMPHOLDER FOR TESTING CONTACT-MARKING EN60061-3 IEC60061-3 7006-30-2
G01.09 PLUG GAUGE FOR LAMPHOLDERS E14 WITH CANDLE SHAPED SHAFT FOR CANDLE LAMPS FOR TESTING CONACT-MARKING EN60061-3 IEC60061-3 7006-30A-1
G01.10 GAUGE FOR TESTING CONTACT-MARKING AND PROTECTION AGAINST ACCIDENTAL CONTACT DURING INSERTION OF LAMPS IN LAMPHOLDERS E14 EN60061-3 IEC60061-3 7006-31-4
G01.11 “GO” GAUGE FOR E27 CAPS ON FINISHED LAMPS EN60061-3 IEC60061-3 7006-27B-1
G01.12 "NOT GO" GAUGE FOR E27 CAPS ON FINISHED LAMPS EN60061-3 IEC60061-3 7006-28A-1
G01.13 GAUGE FOR FINISHED LAMPS FITTED WITH E27 CAPS FOR TESTING CONTACT-MAKING EN60061-3 IEC60061-3 7006-50-1
G01.14 GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT DURING INSERTION E27 EN60061-3 IEC60061-3 7006-51A-2
G01.15 GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT E27/51X39 EN60061-3 IEC60061-3 7006-51-2
G01.16 "GO" GAUGE FOR DIMENSION "S1" OF E27 CAPS ON FINISHED LAMPS EN60061-3 IEC60061-3 7006-27C-1
G01.17 "GO" GAUGE FOR LAMPHOLDERS E27 EN60061-3 IEC60061-3 7006-25A-2
G01.18 "NOT GO" GAUGES FOR SCREW THREADS OF LAMPHOLDERS E10, EP10, EY10, E14, E27, E39 & E40 EN60061-3 IEC60061-3 7006-26-4
G01.19 GAUGE FOR TESTING PROTECTION AGAINST BULB-NECK DAMAGE AND FOR TESTING CONTACT-MAKING IN LAMPHOLDERS E27 EN60061-3 IEC60061-3 7006-21-5
G01.20 GAUGE FOR TESTING CONTACT-MAKING AND PROTECTION AGAINST ACCIDENTAL CONTACT DURING INSERTION OF LAMPS IN LAMPHOLDERS E27 EN60061-3 IEC60061-3 7006-22A-4
G01.21 GAUGE FOR DETECTING SIDE-CONTACTS WITH CUTTING-EDGES IN LAMPHOLDERS E27 EN60061-3 IEC60061-3 7006-22B-1
G01.22 GAUGE I FOR CHECKING SIDE-CONTACT RESILIENCY IN LAMPHOLDERS E27 EN60061-3 IEC60061-3 7006-22C-1
G01.23 GAUGE II FOR CHECKING SIDE-CONTACT RESILIENCY IN LAMPHOLDERS E27 EN60061-3 IEC60061-3 7006-22D-1
G01.24 "GO" GAUGE FOR CAPS E26, E26/50X39, E26/51X39 & E26D EN60061-3 IEC60061-3 7006-27D-2
G01.25 GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT E26D EN60061-3 IEC60061-3 7006-29A-2
G01.26 GAUGE FOR TESTING CONTACT-MAKING OF LAMPS FITTED WITH CAPS E26, E26/50X39, E26/51X39 & E26D (NON-SKIRTED) EN60061-3 IEC60061-3 7006-29-3
G01.27 GAUGE WITH REFERENCE DIAMETER OF 23 MM FOR CAPS E26D EN60061-3 IEC60061-3 7006-29B-2
G01.28 GAUGE WITH REFERENCE DIAMETER OF 13,2 MM FOR CAPS E26D EN60061-3 IEC60061-3 7006-29C-2
G01.29 GAUGE WITH REFERENCE DIAMETER OF 10,4 MM FOR E26D CAPS ON FINISHED LAMPS EN60061-3 IEC60061-3 7006-29D-1
G01.30 "NOT GO"GAUGE FOR CAPS E26, E26/50X39, E26/51X39& E26D EN60061-3 IEC60061-3 7006-29L-4
G01.31 GO" PLUG GAUGE FOR LAMPHOLDERS E26D EN60061-3 IEC60061-3 7006-29K-1
G01.32 NOT GO" GAUGE FOR LAMPHOLDERS E26 & E26D......... EN60061-3 IEC60061-3 7006-26A-2
G01.33 "GO" GAUGE FOR LAMPHOLDERS E26 EN60061-3 IEC60061-3 7006-25B-2
G01.34 GAUGE FOR TESTING CONTACT-MAKING IN LAMPHOLDERS E26D EN60061-3 IEC60061-3 7006-29G-3
G01.35 GAUGE FOR TESTING CONTACT-MAKING IN METAL-SHELL PAPER-LINED LAMPHOLDERS E26D EN60061-3 IEC60061-3 7006-29H-3
G01.36 GAUGE FOR TESTING UNACCEPTABLE CONTACT-MAKING IN LAMPHOLDERS E26D EN60061-3 IEC60061-3 7006-29M-1
G01.37 GAUGES FOR TESTING THE RELATIVE POSITIONS OF THE CONTACTS IN LAMPHOLDERS E26D EN60061-3 IEC60061-3 7006-29F-2
G01.38 PLUG GAUGE FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT IN E26D LAMPHOLDER EN60061-3 IEC60061-3 7006-29J-1
G01.39 GAUGE FOR TESTING CONTACT-MAKING IN LAMPHOLDERS E26 EN60061-3 IEC60061-3 7006-25J-1
G01.40 GAUGE FOR CHECKING THE RADIAL POSITION OF THE INTERMEDIATE CONTACT OF LAMPHOLDER E26D EN60061-3 IEC60061-3 7006-29E-1
G01.41 "GO" GAUGE FOR CAPS ON FINISHED LAMPS E40 EN60061-3 IEC60061-3 7006-27-7
G01.42 "NOT GO" GAUGE FOR CAPS ON FINISHED LAMPS E40 EN60061-3 IEC60061-3 7006-28D-1
G01.43 GAUGE FOR FINISHED LAMPS FITTED WITH E40 CAPS FOR TESTING CONTACT-MAKING EN60061-3 IEC60061-3 7006-52-1
G01.44 GAUGE FOR FINISHED LAMPS FITTED WITH E40 CAPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT EN60061-3 IEC60061-3 7006-53-1
G01.45 "GO" GAUGES FOR SCREW THREADS OF LAMPHOLDERS E10, E14 & E40 EN60061-3 IEC60061-3 7006-25-7
G01.46 "NOT GO" GAUGES FOR SCREW THREADS OF LAMPHOLDERS E10, EP10, EY10, E14, E27, E39 & E40 EN60061-3 IEC60061-3 7006-26-4
G01.47 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT E40 EN60061-3 IEC60061-3 7006-24-3
G01.48 GAUGE FOR TESTING PROTECTION AGAINST BULB-NECK DAMAGE AND FOR TESTING CONTACT-MAKING IN LAMPHOLDERS E40 EN60061-3 IEC60061-3 7006-23-3
G01.49 "GO" GAUGE FOR CAPS ON FINISHED LAMPS E39 EN60061-3 IEC60061-3 7006-24B-1
G01.50 "NOT GO" GAUGE FOR CAPS ON FINISHED LAMPS E39 EN60061-3 IEC60061-3 7006-24C-1
G01.51 GAUGE FOR FINISHED LAMPS FITTED WITH E39 CAPS FOR TESTING CONTACT-MAKING EN60061-3 IEC60061-3 7006-24A-1
G01.52 "GO" GAUGE FOR SCREW THREAD OF LAMPHOLDERS E39 EN60061-3 IEC60061-3 7006-24E-1
G01.53 "NOT GO" GAUGES FOR SCREW THREADS OF LAMPHOLDERS E10, EP10, EY10, E14, E27, E39 & E40 EN60061-3 IEC60061-3 7006-26-4
G01.54 GAUGE FOR TESTING PROTECTION AGAINST BULB-NECK DAMAGE AND FOR TESTING CONTACT-MAKING IN LAMPHOLDERS E39 EN60061-3 IEC60061-3 7006-24D-1
G01.55 GAUGE FOR TESTING MAXIMUM INSERTION TORQUE IN LAMPHOLDERS WITH SHELL-GRIP FEATURES E39. EN60061-3 IEC60061-3 7006-24F-1
G01.56 GAUGE FOR TESTING MINIMUM TORQUE IN LAMPHOLDERS WITH SHELL-GRIP FEATURES E39 EN60061-3 IEC60061-3 7006-24G-1
G01.57 "GO" AND "NOT GO" GAUGE FOR BI-PIN CAP ON FINISHED LAMPS G23 EN60061-3 IEC60061-3 7006-69-2
G01.58 "GO" AND "NOT GO" GAUGE FOR BI-PIN CAP ON FINISHED LAMPS GX23 EN60061-3 IEC60061-3 7006-86-1
G01.59 "GO" AND "NOT GO" GAUGE FOR CAPS ON FINISHED LAMPS 2G7 & 2GX7 EN60061-3 IEC60061-3 7006-102-1
G01.60 "GO" GAUGE FOR CAPS ON FINISHED LAMPS 2G11 EN60061-3 IEC60061-3 7006-82-1
G01.61 "NOT GO" GAUGES "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS G24, GX24 & GY24. EN60061-3 IEC60061-3 7006-78F-5
G01.62 "GO" GAUGE FOR CHECKING THE PINS OF CAPS ON FINISHED LAMPS GR8 & GR10Q EN60061-3 IEC60061-3 7006-68E-1
G01.63 "GO" AND "NOT GO" GAUGE FOR CHECKING THE PINS OF CAPS (NOT FOR USE ON FINISHED LAMPS)GR8 & GR10Q EN60061-3 IEC60061-3 7006-68F-1
G01.64 GAUGE FOR CAPS TO ENSURE ENTRY OF MAXIMUM LAMPHOLDERS AND TO CHECK PIN-SPACING AND LENGTH GR8 EN60061-3 IEC60061-3 7006-68A-2
G01.65 ?GO? GAUGES FOR CAPS 2G13 EN60061-3 IEC60061-3 7006-33-2
G01.66 "GO" GAUGE FOR CAPS G10Q, GX10Q, GY10Q & GZ10Q EN60061-3 IEC60061-3 7006-79-2
G01.67 GAUGE FOR CAPS TO ENSURE ENTRY OF MAXIMUM LAMPHOLDERS AND TO CHECK PIN-SPACING AND LENGTH GR10Q EN60061-3 IEC60061-3 7006-77A-2
G01.68 "GO" GAUGE FOR CAPS ON FINISHED LAMPS GX10Q EN60061-3 IEC60061-3 7006-84-2
G01.69 "NOT GO" GAUGE "A" FOR CAPS ON FINISHED LAMPS GX10Q EN60061-3 IEC60061-3 7006-84A-1
G01.70 "NOT GO" GAUGE "B" FOR CAPS ON FINISHED LAMPS GX 10Q EN60061-3 IEC60061-3 7006-84B-1
G01.71 "GO" GAUGE FOR CAPS ON FINISHED LAMPSGY10Q EN60061-3 IEC60061-3 7006-85-2
G01.72 "NOT GO" GAUGE "A" FOR CAPS ON FINISHED LAMPS GY10Q EN60061-3 IEC60061-3 7006-85A-1
G01.73 "GO" GAUGES FOR THE KEYS OF CAPS ON FINISHED LAMPS GY10Q EN60061-3 IEC60061-3 7006-85D-1
G01.74 "NOT GO" GAUGES FOR CAPS ON FINISHED LAMPS GY10Q EN60061-3 IEC60061-3 7006-85E-1
G01.75 "GO" AND "NOT GO" GAUGES FOR BI-PIN LAMP BASES G4 EN60061-3 IEC60061-3 7006-72-1
G01.76 "GO"AND "NOT GO" GAUGE FOR UNMOUNTED BI-PIN CAP (NOT FOR USE ON FINISHED LAMPS) G5 EN60061-3 IEC60061-3 7006-46-3
G01.77 "GO" GAUGE FOR BI-PIN CAP ON FINISHED LAMPS G5 EN60061-3 IEC60061-3 7006-46A-3
G01.78 "GO" AND "NOT GO" GAUGE FOR UNMOUNTED BI-PIN CAP (NOT FOR USE ON FINISHED LAMPS) G13 EN60061-3 IEC60061-3 7006-44-4
G01.79 "GO" GAUGE FOR BI-PIN CAP ON FINISHED LAMPS G13 EN60061-3 IEC60061-3 7006-45-4
G01.80 DOUBLE-ENDED GAUGES FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACTMAKING G5 EN60061-3 IEC60061-3 7006-47B-3
G01.81 DOUBLE-ENDED "GO" GAUGES FOR A COMBINED PAIR OF LAMPHOLDERS G5 EN60061-3 IEC60061-3 7006-47C-3
G01.82 DOUBLE-ENDED GAUGES FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING G13 EN60061-3 IEC60061-3 7006-60B-4
G01.83 DOUBLE-ENDED "GO" GAUGES FOR A COMBINED PAIR OF LAMPHOLDERS G13 EN60061-3 IEC60061-3 7006-60C-3
G01.84 "GO" GAUGES FOR BASES G6.35, GX6.35 & GY6.35 EN60061-3 IEC60061-3 7006-61A-3
G01.85 GAUGE "A" FOR LAMPHOLDERS S14D EN60061-3 IEC60061-3 7006-112D-1
G01.86 GAUGES "B1" AND "B2" FOR LAMPHOLDERS S14D EN60061-3 IEC60061-3 7006-112E-1
G01.87 GAUGE "A" FOR LAMPHOLDERS S14S. EN60061-3 IEC60061-3 7006-112A-1
G01.88 GAUGE "B" FOR LAMPHOLDERS S14S EN60061-3 IEC60061-3 7006-112B-1
G01.89 GAUGE "C" FOR LAMPHOLDERS S14S EN60061-3 IEC60061-3 7006-112C-1
G01.90 "GO" GAUGE FOR BASE G9 EN60061-3 IEC60061-3 7006-129-1
G01.91 "GO" AND "NOT GO" GAUGE FOR BASES GU10 EN60061-3 IEC60061-3 7006-121-1
G01.92 SINGLE-PIN GAUGE "E" FOR CHECKING MINIMUM RETENTION FORCE OF CONTACTS IN LAMPHOLDERS 2G(X)7, 2G10, 2G11, G(X)23, G(X)(Y)24, G(X)(Y)32 EN60061-3 IEC60061-3 7006-69E-3
G01.93 "NOT GO" GAUGES "F" FOR CHECKING NON-INTERCHANGEABILITYOF CAPS IN LAMPHOLDERS G24, GX24 & GY24 EN60061-3 IEC60061-3 7006-78F-5
G01.94 "GO" GAUGE FOR R17D LAMPHOLDERS EN60061-3 IEC60061-3 7006-57A-1
G01.95 CONTACT-MAKING GAUGE FOR LAMPHOLDER R17D EN60061-3 IEC60061-3 7006-57B-1
G01.96 GAUGES FOR TESTING INSERTION AND CONTACT-MAKING IN LAMPHOLDERS 2G13 EN60061-3 IEC60061-3 7006-33A-2
G01.97 GAUGES FOR TESTING THE INSERTION OF CAPS IN LAMPHOLDERS B15D, B22D & BY22D EN60061-3 IEC60061-3 7006-4A-2
G01.98 GAUGES FOR TESTING THE RETENTION OF B15D AND B22D CAPS IN THE HOLDER EN60061-3 IEC60061-3 7006-4B-1
G01.99 "NOT GO" GAUGES FOR CAPS ON FINISHED LAMPS BA9, B15, B22 & BY22D EN60061-3 IEC60061-3 7006/10/8
G01.100 "GO" GAUGES FOR CAPS ON FINISHED LAMPS BA9, B15, BA15 & B22. EN60061-3 IEC60061-3 7006/11/8
G01.101 ACCEPTANCE GAUGE FOR B22D CAPS INTENDED FOR AUTOMATIC WIRE THREADING EN60061-3 IEC60061-3 7006/3/1
G01.102 "NOT GO"/RETENTION GAUGE FOR LAMPHOLDERS B15 EN60061-3 IEC60061-3 7006-12D-2
G01.103 SUPPLEMENTARY "GO" GAUGE FOR LAMPHOLDERS B15D EN60061-3 IEC60061-3 7006-12C-2
G01.104 GAUGES FOR SLOTS IN LAMPHOLDERS B15D, B22D, B22D-3 & BY22D EN60061-3 IEC60061-3 7006-13-5
G01.105 GAUGE FOR CHECKING CONTACT POSITION AND CONTACT FORCE IN BAYONET LAMPHOLDERS B15D EN60061-3 IEC60061-3 7006-15B-1
G01.106 GAUGES FOR TESTING THE INSERTION OF CAPS IN LAMPHOLDERS B15D, B22D & BY22D EN60061-3 IEC60061-3 7006-4A-2
G01.107 GAUGES FOR TESTING THE RETENTION OF B15D AND B22D CAPS IN THE HOLDER EN60061-3 IEC60061-3 7006-4B-1
G01.108 GAUGES FOR TESTING THE RETENTION OF B15D AND B22D CAPS IN THE HOLDER EN60061-3 IEC60061-3 7006/10/8
G01.109 "GO" GAUGES FOR CAPS ON FINISHED LAMPS BA9, B15, BA15 & B22 EN60061-3 IEC60061-3 7006/11/8
G01.110 PLUG GAUGES FOR LAMPHOLDERS BA21, B15 & B22 EN60061-3 IEC60061-3 7006/12/8
G01.111 GAUGE FOR CHECKING CONTACT POSITION AND CONTACT FORCE IN BAYONET LAMPHOLDERS B22D-3 (90°/135°) EN60061-3 IEC60061-3 7006-15-7
G01.112 PLUG GAUGE FOR BAYONET LAMPHOLDER B22D-3 (90°/135°) EN60061-3 IEC60061-3 7006-20-4
G01.113 SUPPLEMENTARY "GO" GAUGES FOR LAMPHOLDERS B22D & BY22D . EN60061-3 IEC60061-3 7006-12A-2
G01.114 "NOT GO"/RETENTION GAUGE FOR LAMPHOLDERS B22 EN60061-3 IEC60061-3 7006-12B-2
G01.115 GAUGES FOR CHECKING CONTACT POSITION AND CONTACT FORCE IN BAYONET LAMPHOLDERS B22D & BY22D EN60061-3 IEC60061-3 7006-15A-2
G01.116 GAUGES FOR SLOTS IN LAMPHOLDERS B15D, B22D, B22D-3 & BY22D EN60061-3 IEC60061-3 7006-13-5
G01.117 PLUG GAUGE FOR LAMPHOLDERS BY22D EN60061-3 IEC60061-3 7006-17B-1

G01.01
“GO”GAUGE FOR E14 CAPS ON FINISHED LAMPS
EN60061-3
IEC60061-3
7006-27F-1


G01.02
“NOT GO” GAUGE FOR E14 CAPS ON FINISHED LAMPS
EN60061-3
IEC60061-3
7006-28B-1


G01.03
GAUGE FOR FINISHED LAMPS FITTED WITH E14 CAPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT
EN60061-3
IEC60061-3
7006-55-2


G01.04
GAUGE FOR FINISHED LAMPS FITTED WITH E14 CAPS FOR TESTING CONTACT-MAKING
EN60061-3
IEC60061-3
7006-54-2


G01.05
“GO”GAUGE FOR DIMENSION”S1” OF E14 CAPS ON FINISHED LAMPS
EN60061-3
IEC60061-3
7006-27G-1


G01.06
“GO”GAUGES FOR SCREW THREADS OF LAMPHOLDERS E10,E14&E40
EN60061-3
IEC60061-3
7006-25-7


G01.07
“NOT GO”GAUGE FOR SCREW THREADS OF LAMPHOLDERS E10,EP10,EY10,E14,E27,E39&E40
EN60061-3
IEC60061-3
7006-26-4


G01.08
PLUG GAUGE FOR E14 LAMPHOLDER FOR TESTING CONTACT-MARKING
EN60061-3
IEC60061-

CONTACT US

Contact: Eason Wang

Phone: +86-13751010017

Tel: +86-755-33168386

Email: info@iec-equipment.com

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

close
Scan the qr codeClose
the qr code